Acid Resistant Coating for Concrete and Steel
Industrial infrastructure requires robust surface protection against chemical exposure. An acid resistant coating is designed to protect concrete and steel substrates from chemical attack, helping reduce premature deterioration and surface damage.
Chemical suitability depends on several factors, including the specific chemical, concentration, operating temperature and exposure conditions. No single coating provides universal protection against all chemicals, making correct product selection essential for long-term asset protection.
Why Use an Acid Resistant Coating?
Concrete and steel can deteriorate when exposed to acids and other aggressive chemicals. An acid resistant coating provides a protective barrier that helps reduce chemical attack and surface deterioration.
For industrial assets, the right coating can help protect surfaces in areas such as chemical bunds, secondary containment, wastewater facilities, industrial floors and walls.
Product selection should consider the chemical type, concentration, temperature and exposure conditions to ensure the coating system is appropriate for the application.
Recommended Products
Liquimix offers 100% solids epoxy novolac systems designed for chemical, water and anti-corrosion resistance in demanding industrial environments.
- Novolox XT600: A solvent-free epoxy novolac coating with high chemical, water and anti-corrosion resistance for concrete and steel.
- Novolox XT900: A solvent-free epoxy novolac coating with high chemical, water and anti-corrosion resistance, suitable for concrete and steel applications.
Novolox XT600 vs Novolox XT900 Comparison
The table below compares the key specifications of the two acid resistant coating systems to help with product selection.
| Specification | Novolox XT600 | Novolox XT900 |
|---|---|---|
| Product Type | Solvent-free epoxy novolac | Solvent-free epoxy novolac |
| Volume Solids | 100% | 100% |
| Chemical Resistance | High chemical, water and anti-corrosion resistance | High chemical, water and anti-corrosion resistance |
| Typical DFT | 125–300 µm | 125–500 µm |
| Mix Ratio | 2:1 by volume | 3:1 by volume |
| Pot Life at 25°C | 45 minutes | 45 minutes |
| Theoretical Coverage | 5 m²/L at 200 µm DFT | 3.33 m²/L at 300 µm DFT |
| Substrates | Concrete and steel | Concrete and steel |
| Typical Applications | Secondary containment, chemical bunding, industrial floors and walls, wastewater, pulp and paper, sewerage contact | Secondary containment, chemical bunding, industrial floors and walls, wastewater, pulp and paper, sewerage contact |
| Key Difference | DFT up to 300 µm; TDS does not recommend continuous chemical immersion | DFT up to 500 µm; TDS specifies systems for steel tank internal immersion |
Important: Product selection should be based on the specific chemical, concentration, temperature and exposure conditions. Always refer to the current TDS and SDS before specification or application.
Typical Applications
Novolox epoxy novolac coatings are designed for demanding industrial environments. Typical applications include:
- Chemical bunding and secondary containment
- Industrial floors and walls exposed to chemical splash or spillage
- Wastewater and sewerage areas
- Pulp and paper facilities
- Steel tanks where specified in the system design
Surface Preparation
Proper surface preparation is essential for coating adhesion and performance.
Concrete: Concrete should generally be at least 28 days old with moisture below 7%. Remove oil, grease, laitance and other contaminants using suitable mechanical preparation. Acid etching is not an acceptable preparation method.
Steel: Remove rust, mill scale, oil and existing coatings, then abrasive blast to the preparation standard and profile specified in the relevant TDS.
Application Guidelines
Applying an acid resistant coating requires careful substrate preparation and application:
- Inspect: Ensure the substrate is clean, dry and properly prepared.
- Prime: Apply the specified compatible primer where required. Novolox XT900 uses Civilox-LV100 on concrete.
- Mix: Follow the specified mix ratio—2:1 for XT600 and 3:1 for XT900.
- Apply: Apply evenly to achieve the required dry film thickness (DFT).
- Cure: Allow sufficient curing time before service. Full properties develop over up to 14 days, depending on conditions.
Always follow the current TDS and SDS for project-specific requirements.
Product Selection
When selecting an acid resistant coating, consider:
- Chemical type and concentration
- Operating temperature
- Splash, spill or immersion exposure
- Substrate and surface condition
- Required dry film thickness
Contact the Liquimix technical team to confirm suitability for your specific chemical exposure.
Limitations and Safety
- Appearance: Exposed Novolox XT600 and XT900 may experience colour change and surface chalking over time.
- Immersion: XT600 is not recommended for continuous chemical immersion.
- Curing: Allow adequate time for the coating to develop its specified physical properties.
- Professional use: Follow the current TDS, SDS and applicable Australian workplace health and safety requirements.
Need Help with Your Chemical Protection Project?
Choosing the right acid resistant coating depends on your substrate, chemical exposure and operating conditions. Contact Liquimix to discuss your project requirements and product options.