Meat processing facilities and abattoirs expose concrete and steel surfaces to demanding operating conditions, including animal fats, greases, vegetable oils, moisture, and cleaning chemicals. Processing floors, drainage channels, walls, and secondary containment areas require careful consideration when selecting protective coating systems.
Frequent washdowns and sanitation procedures can place additional demands on coated surfaces. Without suitable protection and maintenance, contaminants may penetrate porous concrete, while moisture and chemical exposure can contribute to substrate deterioration and steel corrosion.
Novolox XT600 is a two-component, solvent-free epoxy novolac designed for concrete and steel surfaces requiring chemical-resistant protection. Its documented applications include industrial floors and walls exposed to chemicals, chemical bunding, and secondary containment.
However, no single coating system is suitable for every area of a meat processing facility. Chemical concentrations, exposure duration, cleaning temperatures, substrate conditions, and operational requirements must be assessed before specification. Novolox XT600 is not recommended for continuous chemical immersion, so site-specific suitability should be confirmed with the Liquimix Technical Advisory Team.
Why Do Meat Processing Facilities Need Protective Coatings?
Meat processing facilities expose concrete and steel surfaces to fats, oils, moisture, and cleaning chemicals. Without suitable protection, these conditions can contribute to substrate deterioration and corrosion.
Liquimix Novolox XT600 is a chemical-resistant epoxy novolac designed for concrete and steel surfaces. Selecting a suitable coating requires assessing chemical exposure, cleaning conditions, and substrate requirements. Novolox XT600 is not recommended for continuous chemical immersion.
Application Areas and Substrates
Novolox XT600 is designed for concrete and steel surfaces requiring chemical-resistant protection in suitable industrial environments.
Concrete Industrial Floors: For areas exposed to chemical spills, oils, and moisture, subject to compatibility assessment.
Concrete Walls: For surfaces requiring protection against specified chemical exposure.
Secondary Containment Bunds: For concrete containment areas where chemical-resistant coatings are required.
Wastewater Treatment Areas: For suitable surfaces exposed to wastewater and chemicals, subject to exposure assessment.
Structural Steel: For properly prepared steel surfaces requiring chemical and corrosion protection.
Important: Novolox XT600 is not recommended for continuous chemical immersion. Confirm suitability for drainage channels, frequent hot washdowns, and specific abattoir operating conditions with the Liquimix Technical Advisory Team.
System Selection & Operational Suitability
Selecting a suitable coating system for meat processing facilities requires assessing:
Chemical Exposure: Specific chemicals, concentrations, and mixtures.
Operating Temperatures: Ambient conditions and washdown temperatures.
Substrate Preparation: Surface cleanliness, condition, and moisture content.
Exposure Duration: Splash, spills, intermittent contact, or prolonged exposure.
Important: The Novolox XT600 TDS states that the product is not recommended for continuous chemical immersion. Confirm compatibility with the actual chemicals and operating conditions with the Liquimix Technical Advisory Team before specification.
Verified Technical Information
The following physical properties are specified in the Novolox XT600 Technical Data Sheet (TDS).
| Technical Parameter | Verified TDS Specification |
|---|---|
| Volume Solids | 100% |
| Volatile Organic Compounds (VOC) | 0 g/L (mixed) |
| Mixing Ratio | 2:1 by volume |
| Pot Life at 25°C | 45 minutes |
| Theoretical Coverage | 5 m²/L at 200 µm DFT |
| Typical Dry Film Thickness (DFT) | 125–300 µm |
| Dry Heat Resistance | Up to 100°C |
| Substrates | Properly prepared concrete and steel |
Disclaimer: These published technical properties do not, on their own, establish suitability for every meat processing or abattoir environment. Chemical compatibility, cleaning procedures, operating temperatures, exposure duration, and substrate conditions must be assessed for each project. Novolox XT600 is not recommended for continuous chemical immersion. Consult the Liquimix Technical Advisory Team to confirm site-specific suitability before specification.
Recommended Liquimix Product
Novolox XT600
100% Volume Solids Chemically Resistant Epoxy Novolac
Novolox XT600 is a two-component, solvent-free epoxy novolac coating designed for concrete and steel surfaces requiring chemical, water, and anti-corrosion resistance.
Verified Product Benefits
100% Volume Solids, 0 g/L VOC: Solvent-free formulation with zero mixed VOC, according to the TDS.
Chemical and Water Resistance: Designed for industrial floors and walls exposed to chemicals, chemical bunding, and secondary containment.
Concrete and Steel Protection: Provides a protective coating for suitably prepared concrete and steel substrates.
Practical Application: Features a 2:1 mixing ratio by volume and a 45-minute pot life at 25°C.
Important: Confirm chemical compatibility and site suitability before specification. Novolox XT600 is not recommended for continuous chemical immersion.
Suitable Applications Supported by the TDS
Industrial Floors and Walls: Surfaces exposed to chemicals in suitable industrial environments.
Secondary Containment and Chemical Bunding: Concrete surfaces requiring chemical-resistant protection.
Wastewater Areas: Assess chemical compatibility and exposure conditions before specification.
Concrete and Steel Substrates: Suitable when properly prepared and used within the product’s documented limitations.
Documentation and Product Enquiries
System and Application Considerations
Proper substrate preparation is essential for coating adhesion and performance.
Surface Preparation
Decontamination: Remove fats, oils, grease, release agents, and other contaminants before coating.
Concrete Substrates: Concrete must be at least 28 days old, with moisture content below 7%. Prepare the surface to the specified profile using approved mechanical methods. Acid etching is not acceptable.
Steel Substrates: Remove rust, mill scale, oil, grease, and existing coatings. Abrasive blast to Sa 2½ or SSPC-SP10, with a recommended surface profile of 75–100 microns.
Important: Novolox XT600 is not recommended for continuous chemical immersion. Confirm site-specific suitability with Liquimix before specification.
Priming & Application
Primer System: Apply Civilox-LV100 to concrete as specified in the TDS. This helps minimise pinholing caused by concrete outgassing. Additional primer coats may be required depending on substrate porosity.
Mixing & Environmental Controls: Mix Part A and Part B at the specified 2:1 ratio by volume. Ensure relative humidity is below 85%, substrate temperature is above 5°C, and the substrate temperature is at least 3°C above the dew point.
Chemical Compatibility: Confirm chemical type, concentration, temperature, and exposure duration with the Liquimix Technical Advisory Team before specification.
Note: This summary does not replace the full application procedure. Always consult the current TDS, SDS, and project specifications before application.
Technical Documentation
Access Liquimix product information and technical resources for Novolox XT600:
For the latest Novolox XT600 Technical Data Sheet (TDS) and Safety Data Sheet (SDS), contact the Liquimix Technical Advisory Team if the current documents are not available on the product page.
Always verify the current technical documentation, chemical compatibility, and project-specific coating requirements before specification and application.
Related Applications & Systems
Request a Specification
Planning a protective coating system for a meat processing facility or abattoir? Contact the Liquimix Technical Advisory Team for product selection, chemical compatibility assessment, and project-specific specification support.