Polyurethane (PU) Floor Coatings: PureStep PU75 Pigmented

Protect concrete floors with PureStep PU75 Pigmented, a polyurethane coating for Australian commercial and industrial flooring applications.

Overview of Polyurethane (PU) Floor Coatings

Concrete floors in commercial, industrial and residential environments require protection against abrasion, traffic and environmental exposure. Polyurethane (PU) floor coatings can provide a durable finish when selected and applied according to project requirements.

PureStep PU75 is a two-component polyurethane coating manufactured by Liquimix, with 75% volume solids.  Available in clear or pigmented finishes, it is designed for suitable, properly prepared substrates. Confirm compatible primers, colour availability, application conditions and performance requirements with Liquimix before specifying the system.

Application Overview

Polyurethane (PU) floor coatings provide a protective finish for suitable concrete flooring systems in commercial and industrial environments. PureStep PU75 Pigmented is a two-component polyurethane coating available in pigmented and clear finishes.

With 75% volume solids. PU75 forms a coating film on properly prepared substrates. Its suitability for interior or exterior use, wear resistance, recoat intervals and drying times should be confirmed against the current manufacturer documentation and project requirements.

For reliable performance, follow Liquimix recommendations for substrate preparation, mixing, application conditions and compatible primers.

Features

  • Excellent UV resistance

  • User-Friendly application

  • Outstanding Wear Resistant with Flexibility

  • Effortless Cleaning and Maintenance

  • Long Pot Life

UV performance, drying times, abrasion resistance, chemical resistance, impact resistance and return-to-service times must be confirmed against current technical documentation.

Suitable Applications

PureStep PU75 Pigmented may be considered for suitable concrete flooring projects where a pigmented polyurethane finish is required, subject to substrate compatibility and manufacturer approval.

Potential project settings to assess include:

  • Commercial Facilities: Retail spaces, showrooms and corridors.

  • Industrial Facilities: Warehouses, workshops and light manufacturing areas.

  • Garages and Vehicle Areas: Floors subject to vehicle traffic, provided the coating system is approved for the expected loads and exposure.

  • Public Buildings: Selected areas where the required cleaning, slip resistance and service conditions can be met.

  • Exterior Concrete: Only where exterior exposure and UV performance are confirmed by Liquimix.

Before specifying the product, confirm substrate preparation, primer compatibility, slip-resistance requirements, chemical exposure, traffic loads and curing conditions with the Liquimix technical team.

Substrate Preparation

Proper substrate preparation is essential for achieving reliable adhesion and long-term coating performance. Follow the current Liquimix Technical Data Sheet (TDS) and project specifications.

  1. Concrete Assessment: Ensure the concrete is structurally sound and free from laitance, curing compounds, oil, grease and other contaminants. Confirm concrete age and curing requirements with Liquimix before application.

  2. Mechanical Surface Preparation: Use suitable mechanical preparation, such as diamond grinding or abrasive blasting, to remove weak surface material and provide an appropriate surface profile for the specified coating system.

  3. Moisture Assessment: Check substrate moisture and environmental conditions against the manufacturer’s requirements. Where moisture may affect adhesion, obtain technical advice on suitable mitigation measures before proceeding.

  4. Surface Cleaning: Remove dust and loose debris using suitable industrial vacuum equipment. Ensure the prepared surface meets the coating system’s cleanliness and dryness requirements before applying primer or coating.

 

Application Methodology

Environmental Conditions

Check ambient temperature, substrate temperature, humidity and dew point before application. Apply PureStep PU75 only within the environmental limits specified in the current Liquimix Technical Data Sheet (TDS). Ensure the substrate is free from condensation and suitable for coating.

Mixing Instructions

PureStep PU75 is a two-component polyurethane coating. The available TDS specifies a 4:1 mixing ratio by volume (Part A : Part B); confirm this against the current product documentation before use.

  1. Pre-mix Part A as directed by the manufacturer.

  2. Add Part B in the specified proportion.

  3. Mix using suitable mechanical equipment according to the manufacturer’s instructions, ensuring both components are thoroughly incorporated.

  4. Apply the mixed material within the confirmed pot life. Avoid introducing excessive air during mixing.

Application Equipment and Technique

Use only application equipment approved for PureStep PU75 in the current TDS.

  • Roller: Use a compatible roller suitable for the product and substrate.

  • Brush: Use for edges and restricted areas where permitted.

  • Airless Spray: Confirm equipment compatibility, nozzle specifications and application parameters with Liquimix before spraying.

Apply the coating evenly and maintain the specified film thickness. Follow manufacturer instructions for the number of coats and any compatible primer or intermediate coating.

Recoat and Drying Windows

Drying and recoat times vary with substrate temperature, ambient conditions, humidity, film thickness and ventilation. Consult the current Liquimix TDS for verified tack-free, hard-dry, minimum recoat and maximum recoat times.

If the maximum recoat interval is exceeded, follow the manufacturer’s surface preparation instructions before applying another coat. Do not assume that sanding alone is sufficient for every situation.

Applicator rolling a grey floor coating onto prepared concrete in an industrial facility.
Illustrative image of polyurethane floor coating application on a prepared concrete substrate.

Typical Flooring System Configurations

A polyurethane floor coating system must be selected according to substrate condition, exposure, traffic requirements and compatibility between coating layers.

LayerSystem ComponentSelection Requirements
1. SubstratePrepared concreteSound, clean and prepared to Liquimix requirements
2. PrimerCompatible primerConfirm suitability with Liquimix Technical Support
3. Intermediate CoatOptional base coatInclude only where specified for the approved system
4. TopcoatPureStep PU75 PigmentedApply according to the current TDS and specified film thickness

Important: Do not combine Aralox FL170, Civilox LV100, Aralox Premium or other products into a recommended system without manufacturer confirmation. The number of coats and application thickness must follow the approved system specification.

Contact Liquimix Technical Support for project-specific recommendations.

Technical Specifications

The following values are reported in the available PureStep PU75 TDS. 

PropertyReported Specification
Product TypeTwo-component polyurethane coating
Volume Solids75%
Mixing Ratio4:1 by volume (Part A : Part B)
Theoretical Coverage8 m²/L at 94 µm DFT
Typical DFT60–94 µm
Pot Life at 25°C2 hours
VOC Content317.4 g/L
Flash Point22°C
Cleaner / ThinnerLM1 Thinner
FinishClear or pigmented; confirm available finishes and gloss level

Theoretical coverage is an estimate and may vary with substrate profile, porosity, application technique and material losses. Confirm colour availability, specific gravity, wet film thickness and approved system configurations with Liquimix before publishing.

Close-up of a smooth, glossy floor coating finish. Illustrative image only; actual PureStep PU75 performance depends on the specified system and application conditions.

Limitations, Health & Safety

Application Limitations

  • Pot life is dependent on mix temperature

  • Thin-film dry times are dependent on temperature and film thickness

  • Thicker films will take longer to cure through
  • Higher cure temperature and direct exposure to the sun will shorten the recoat times

Health & Safety Precautions

  • Flammability: The available TDS lists a flash point of 22°C. Keep the product away from ignition sources and follow the current SDS.

  • Ventilation: Provide suitable ventilation during mixing and application, following the SDS requirements.

  • Personal Protective Equipment (PPE): Use appropriate gloves, eye protection, protective clothing and respiratory protection as specified in the SDS and workplace risk assessment.

  • Safe Handling: Read the current Safety Data Sheets for both components before use. Follow all handling, storage, spill response and disposal instructions.

Frequently Asked Questions (FAQ)

1. What is the difference between epoxy and polyurethane (PU) floor coatings?

Epoxy is not UV stable and will have some colour change and chalking over time. It does have excellent chemical resistance. Polyurethane has excellent colour stability and decorative appearance. 

2. Can PureStep PU75 Pigmented be applied directly to bare concrete?

Do not assume direct application is suitable. Concrete preparation and primer requirements depend on the substrate condition and approved coating system. Confirm the appropriate primer and application method with Liquimix Technical Support.

3. How long does PureStep PU75 take to dry?

Drying and curing times depend on temperature, humidity, film thickness and ventilation. Consult the current Liquimix TDS for verified drying times and requirements before opening the floor to traffic.

4. What coverage can I expect per litre?

The available TDS lists a theoretical coverage of 8 m²/L at 94 µm dry film thickness (DFT). Actual coverage may vary with substrate profile, porosity, application technique and material losses.

Suggested Internal Links for Liquimix

Related Products

Glossy grey polyurethane floor coating in a commercial industrial facility

Contact Liquimix Technical Support

Need help selecting a suitable polyurethane floor coating system? Contact Liquimix for product specifications, substrate preparation guidance, application advice and technical documentation.

Contact the Liquimix technical team to discuss your project requirements and confirm product suitability before application.

Related Applications

Related News

Key Takeaways Liquimix supplies closed-cell polyurethane spray foam systems in Australia, plus the Graco equipment to apply them. We also offer equipment hire and workshop servicing. Closed-cell foam is the usual choice for cold storage and industrial pipe insulation because it’s rigid and moisture-resistant. It also insulates more per millimetre

Key Takeaways A sunken concrete slab can be lifted and levelled without removal by injecting expanding polyurethane foam through small holes. Foam jacking is lighter and less invasive than mudjacking, and it reacts within seconds. Liquimix manufactures slab lifting foam in Australia and supplies it to professional applicators. Sunken concrete

Key Takeaways To stop water leaking through cracks in a basement car park, inject the cracks with a hydrophilic polyurethane resin. The CrackShot 150, for example, reacts with water to create the perfect seal, even while it’s still leaking. Use epoxy injection for dry, structural cracks instead. The right choice

Key Takeaways The best waterproof coating for a flat concrete roof is a UV-stable, liquid-applied membrane, typically polyurethane or a polyurea hybrid. It forms a seamless layer with no joints, preventing leaks. Trafficable systems (pedestrian-friendly surfaces for walking) suit rooftop terraces, and lifespan depends on UV exposure, membrane thickness, ponding