Understanding Tufflon-P90 for Rubber Lining Repair Systems
Industrial rubber linings and protective surfaces operate in aggressive environments. Over time, abrasion, impact, mechanical wear, chemical exposure and environmental conditions can cause cracking, gouging, surface deterioration or loss of adhesion. If left unaddressed, damage may expose the underlying steel or concrete substrate and increase maintenance requirements.
Tufflon-P90 is a spray-applied pure polyurea designed to provide a tough, seamless and elastomeric protective lining for suitable industrial substrates. With over 350% elongation, high abrasion resistance and chemical resistance, it can be considered for demanding industrial lining and protection applications.
For existing rubber-lined assets, the condition of the lining, substrate, compatibility and adhesion should be assessed before specifying a polyurea repair or protective system.
What Is Tufflon-P90?
Tufflon-P90 is a two-component, 100% solids, spray-applied pure polyurea elastomer designed as a tough, thick-film protective lining for suitable industrial substrates.
Key Technical Attributes
- Composition: 100% solids pure polyurea with 0 g/L VOC.
- Application: Plural-component, high-pressure spray application.
- Hardness: Shore A 90–92 / Shore D 40–42.
- Elongation: >350%, providing high flexibility.
- Seamless Lining: Forms a continuous protective membrane without joints or seams.
- Crack Bridging: Can bridge hairline cracks up to approximately 1.5 mm, subject to substrate condition and system design.
- Resistance: High resistance to abrasion, puncture, impact, acids, alkalis and many petrochemicals.
Rubber Lining Repair and Protection Applications
Tufflon-P90 can be considered for suitable industrial lining and protection applications where abrasion, impact, puncture and chemical exposure are concerns. It does not chemically restore or re-vulcanise degraded rubber; existing rubber-lined surfaces should be assessed for condition, compatibility and adhesion before any polyurea system is specified.
Suitable Application Areas
- Heavy Transport Tippers: Abrasion-resistant lining for tipper bodies handling abrasive materials.
- Wastewater & Sewage Treatment: Lining and refurbishment of suitable areas exposed to chemical and mechanical wear.
- Secondary Containment & Bunds: Seamless protection for fuel and chemical containment areas.
- Industrial Floors: Tough, seamless and easily cleaned surfaces in suitable processing environments.
- General Industrial Protection: Protective lining where a thick, elastomeric barrier is required.
Important: Tufflon-P90 is not suitable for every rubber formulation or substrate. Existing surfaces must be assessed for physical condition, compatibility, surface preparation and adhesion before specifying an overlay or repair system.
Key Performance Advantages
Tufflon-P90 provides a combination of high elongation, tensile strength, tear resistance and abrasion resistance for demanding industrial lining applications.
Physical and Performance Properties
| Property | Tufflon-P90 |
|---|---|
| Volume Solids | 100% |
| VOC Content | 0 g/L |
| Mixing Ratio | 1:1 by volume |
| Gel Time | Approx. 5 seconds |
| Typical DFT | 3,000 microns (3 mm) |
| Elongation | >350% |
| Tensile Strength | 15 MPa |
| Tear Strength | 80–85 N/mm |
| Hardness | Shore A 90–92 / Shore D 40–42 |
| Water Absorption | <1% |
| Specific Gravity | 1.06 |
Abrasion Resistance
Tufflon-P90 has been tested for abrasion resistance using ASTM C501-84 at 1,000 rpm with a 1,000 g load. Reported results include 90 mg using an H18 wheel and 3.1 mg using a CS17 wheel.
These laboratory results provide an indication of abrasion resistance. Actual field performance will depend on factors such as material characteristics, impact, operating conditions, temperature and application quality.
Surface Preparation
Proper substrate assessment and surface preparation are critical to the adhesion and performance of a polyurea lining.
Concrete Substrates
- Age & Moisture: Concrete should be at least 28 days old with moisture below 7%.
- Cleaning: Remove oil, grease, release agents, laitance and other contaminants.
- Surface Profile: Prepare in accordance with SSPC-SP13 / NACE No. 6 using suitable mechanical methods.
- Defect Repair: Repair bug holes, pits and damaged areas with a compatible repair material before priming.
Steel Substrates
- Surface Preparation: Abrasive blast clean to Sa 2.5 / AS 1627.9.
- Blast Profile: Achieve a surface profile of approximately 80 -120 microns.
- Cleanliness: Remove rust, mill scale, oil, grease, dust and soluble salts before application
Existing Rubber-Lined Surfaces
- Inspection: Check the existing rubber for poor adhesion, swelling, contamination or chemical degradation.
- Preparation: Only sound, compatible rubber surfaces should be considered for further preparation and coating.
- Compatibility: Confirm compatibility and adhesion before specifying Tufflon-P90 over an existing rubber lining.
Typical System Configurations
System selection depends on the substrate and service conditions. The Tufflon-P90 TDS provides the following representative systems:
Concrete – Secondary Containment
Civilox LV100 5m² / L or 200 µm soaks in → Civilox-HB200 125 µm → Tufflon-P90 3,000 µm
Steel – Transport Tipper
Civilox-HB200 125 µm → Tufflon-P90 3,000 µm
System design and final DFT should be confirmed against the project requirements and current TDS.
Steel Transport Tipper System
- Primer: Civilox-HB200 – 125 µm DFT, applied to freshly blast-cleaned steel at Sa 2.5.
- Protective Lining: Tufflon-P90 – 3,000 µm (3.0 mm) DFT, spray-applied.
This system provides a tough, seamless polyurea lining for steel tipper bodies exposed to abrasion and impact.
Application Requirements
Tufflon-P90 should be applied by trained and experienced spray-polyurea applicators using suitable professional plural-component spray equipment.
Equipment Settings & Conditions
- Equipment: High-pressure, heated plural-component spray equipment with a 1:1 mixing ratio.
- Material Temperature: Approx. 65°C at the spray gun.
- Pressure: Above 2,000 psi (138 bar).
- Humidity: Below 85% RH.
- Substrate: Minimum 5°C and at least 3°C above dew point.
- Mixing: Mechanically mix Part B as specified in the TDS.
- Thinning: Do not thin Tufflon-P90.
Cure and Service Considerations
Tufflon-P90 cures rapidly, supporting efficient application and return-to-service scheduling.
- Gel Time – 5 seconds
- Walk on – 2 minutes
- Water immersion – 24 hours
- Full Cure –7 days
- Full Physical Properties and Adhesion – May continue developing for up to 14 days
Actual cure times depend on site conditions. Refer to the current TDS for detailed cure and service requirements.
Limitations and Important Considerations
- UV Exposure: Tufflon-P90 is an aromatic polyurea and may change colour with prolonged UV exposure. This does not necessarily indicate loss of physical performance. Use a colour-fast topcoat or aliphatic system where colour retention is important.
- Rubber Compatibility: Existing rubber surfaces must be assessed for condition, compatibility and adhesion before applying Tufflon-P90. It does not chemically repair or re-vulcanise degraded rubber.
- Professional Application: Tufflon-P90 contains isocyanates. Appropriate PPE, ventilation and respiratory protection may be required. Follow the SDS and applicable Australian WHS requirements.
- Documentation: Always consult the current TDS and SDS before specifying or applying Tufflon-P90.
Conclusion
Tufflon-P90 provides a seamless, tough and elastomeric protective lining for suitable industrial substrates. Its high abrasion resistance, chemical resistance and >350% elongation make it suitable for demanding lining and protection applications.
When correctly specified and applied, Tufflon-P90 can help protect steel, concrete and compatible existing linings against abrasion, impact, chemical exposure and industrial wear.
Contact Liquimix
Need help with your protective lining project? Contact the Liquimix technical team to discuss substrate compatibility, system requirements, TDS documentation, or qualified applicator options.