Rubber Lining Repair Systems: Tufflon-P90 Polyurea Protection

Rubber lining repair systems using Tufflon-P90 pure polyurea for durable protection against abrasion, chemicals, impact and industrial wear.

Understanding Tufflon-P90 for Rubber Lining Repair Systems

Industrial rubber linings and protective surfaces operate in aggressive environments. Over time, abrasion, impact, mechanical wear, chemical exposure and environmental conditions can cause cracking, gouging, surface deterioration or loss of adhesion. If left unaddressed, damage may expose the underlying steel or concrete substrate and increase maintenance requirements.

Tufflon-P90 is a spray-applied pure polyurea designed to provide a tough, seamless and elastomeric protective lining for suitable industrial substrates. With over 350% elongation, high abrasion resistance and chemical resistance, it can be considered for demanding industrial lining and protection applications.

For existing rubber-lined assets, the condition of the lining, substrate, compatibility and adhesion should be assessed before specifying a polyurea repair or protective system.

What Is Tufflon-P90?

Tufflon-P90 is a two-component, 100% solids, spray-applied pure polyurea elastomer designed as a tough, thick-film protective lining for suitable industrial substrates.

Key Technical Attributes

  • Composition: 100% solids pure polyurea with 0 g/L VOC.
  • Application: Plural-component, high-pressure spray application.
  • Hardness: Shore A 90–92 / Shore D 40–42.
  • Elongation: >350%, providing high flexibility.
  • Seamless Lining: Forms a continuous protective membrane without joints or seams.
  • Crack Bridging: Can bridge hairline cracks up to approximately 1.5 mm, subject to substrate condition and system design.
  • Resistance: High resistance to abrasion, puncture, impact, acids, alkalis and many petrochemicals.

Rubber Lining Repair and Protection Applications

Tufflon-P90 can be considered for suitable industrial lining and protection applications where abrasion, impact, puncture and chemical exposure are concerns. It does not chemically restore or re-vulcanise degraded rubber; existing rubber-lined surfaces should be assessed for condition, compatibility and adhesion before any polyurea system is specified.

Suitable Application Areas

  • Heavy Transport Tippers: Abrasion-resistant lining for tipper bodies handling abrasive materials.
  • Wastewater & Sewage Treatment: Lining and refurbishment of suitable areas exposed to chemical and mechanical wear.
  • Secondary Containment & Bunds: Seamless protection for fuel and chemical containment areas.
  • Industrial Floors: Tough, seamless and easily cleaned surfaces in suitable processing environments.
  • General Industrial Protection: Protective lining where a thick, elastomeric barrier is required.

Important: Tufflon-P90 is not suitable for every rubber formulation or substrate. Existing surfaces must be assessed for physical condition, compatibility, surface preparation and adhesion before specifying an overlay or repair system.

Dump Truck Bed Before and After
Illustrative image: Tufflon-P90 applied as a seamless, tough polyurea lining to a heavy-duty tipper bed, providing protection against abrasion, impact and demanding industrial wear.

Key Performance Advantages

Tufflon-P90 provides a combination of high elongation, tensile strength, tear resistance and abrasion resistance for demanding industrial lining applications.

Physical and Performance Properties

PropertyTufflon-P90
Volume Solids100%
VOC Content0 g/L
Mixing Ratio1:1 by volume
Gel TimeApprox. 5 seconds
Typical DFT3,000 microns (3 mm)
Elongation>350%
Tensile Strength15 MPa
Tear Strength80–85 N/mm
HardnessShore A 90–92 / Shore D 40–42
Water Absorption<1%
Specific Gravity1.06

Abrasion Resistance

Tufflon-P90 has been tested for abrasion resistance using ASTM C501-84 at 1,000 rpm with a 1,000 g load. Reported results include 90 mg using an H18 wheel and 3.1 mg using a CS17 wheel.

These laboratory results provide an indication of abrasion resistance. Actual field performance will depend on factors such as material characteristics, impact, operating conditions, temperature and application quality.

Surface Preparation

Proper substrate assessment and surface preparation are critical to the adhesion and performance of a polyurea lining.

Concrete Substrates
  • Age & Moisture: Concrete should be at least 28 days old with moisture below 7%.
  • Cleaning: Remove oil, grease, release agents, laitance and other contaminants.
  • Surface Profile: Prepare in accordance with SSPC-SP13 / NACE No. 6 using suitable mechanical methods.
  • Defect Repair: Repair bug holes, pits and damaged areas with a compatible repair material before priming.

Steel Substrates

  • Surface Preparation: Abrasive blast clean to Sa 2.5 / AS 1627.9.
  • Blast Profile: Achieve a surface profile of approximately 80 -120 microns.
  • Cleanliness: Remove rust, mill scale, oil, grease, dust and soluble salts before application

Existing Rubber-Lined Surfaces

  • Inspection: Check the existing rubber for poor adhesion, swelling, contamination or chemical degradation.
  • Preparation: Only sound, compatible rubber surfaces should be considered for further preparation and coating.
  • Compatibility: Confirm compatibility and adhesion before specifying Tufflon-P90 over an existing rubber lining.

Typical System Configurations

System selection depends on the substrate and service conditions. The Tufflon-P90 TDS provides the following representative systems:

Concrete – Secondary Containment
Civilox LV100 5m² / L or 200 µm soaks in → Civilox-HB200 125 µm → Tufflon-P90 3,000 µm

Steel – Transport Tipper
Civilox-HB200 125 µm → Tufflon-P90 3,000 µm

System design and final DFT should be confirmed against the project requirements and current TDS.

Steel Transport Tipper System

  1. Primer: Civilox-HB200 – 125 µm DFT, applied to freshly blast-cleaned steel at Sa 2.5.
  2. Protective Lining: Tufflon-P90 – 3,000 µm (3.0 mm) DFT, spray-applied.

This system provides a tough, seamless polyurea lining for steel tipper bodies exposed to abrasion and impact.

Application Requirements

Tufflon-P90 should be applied by trained and experienced spray-polyurea applicators using suitable professional plural-component spray equipment.

Equipment Settings & Conditions

  • Equipment: High-pressure, heated plural-component spray equipment with a 1:1 mixing ratio.
  • Material Temperature: Approx. 65°C at the spray gun.
  • Pressure: Above 2,000 psi (138 bar).
  • Humidity: Below 85% RH.
  • Substrate: Minimum 5°C and at least 3°C above dew point.
  • Mixing: Mechanically mix Part B as specified in the TDS.
  • Thinning: Do not thin Tufflon-P90.
Illustrative image: Tufflon-P90 provides a seamless, durable polyurea lining for heavy-duty tipper beds, offering protection against abrasion, impact and demanding industrial wear.

Cure and Service Considerations

Tufflon-P90 cures rapidly, supporting efficient application and return-to-service scheduling.

  • Gel Time – 5 seconds
  • Walk on – 2 minutes
  • Water immersion – 24 hours
  • Full Cure –7 days
  • Full Physical Properties and Adhesion – May continue developing for up to 14 days

Actual cure times depend on site conditions. Refer to the current TDS for detailed cure and service requirements.

 

Limitations and Important Considerations

  • UV Exposure: Tufflon-P90 is an aromatic polyurea and may change colour with prolonged UV exposure. This does not necessarily indicate loss of physical performance. Use a colour-fast topcoat or aliphatic system where colour retention is important.
  • Rubber Compatibility: Existing rubber surfaces must be assessed for condition, compatibility and adhesion before applying Tufflon-P90. It does not chemically repair or re-vulcanise degraded rubber.
  • Professional Application: Tufflon-P90 contains isocyanates. Appropriate PPE, ventilation and respiratory protection may be required. Follow the SDS and applicable Australian WHS requirements.
  • Documentation: Always consult the current TDS and SDS before specifying or applying Tufflon-P90.

Conclusion

Tufflon-P90 provides a seamless, tough and elastomeric protective lining for suitable industrial substrates. Its high abrasion resistance, chemical resistance and >350% elongation make it suitable for demanding lining and protection applications.

When correctly specified and applied, Tufflon-P90 can help protect steel, concrete and compatible existing linings against abrasion, impact, chemical exposure and industrial wear.

Contact Liquimix

Need help with your protective lining project? Contact the Liquimix technical team to discuss substrate compatibility, system requirements, TDS documentation, or qualified applicator options.

Related Applications

Related News

Key Takeaways Liquimix supplies closed-cell polyurethane spray foam systems in Australia, plus the Graco equipment to apply them. We also offer equipment hire and workshop servicing. Closed-cell foam is the usual choice for cold storage and industrial pipe insulation because it’s rigid and moisture-resistant. It also insulates more per millimetre

Key Takeaways A sunken concrete slab can be lifted and levelled without removal by injecting expanding polyurethane foam through small holes. Foam jacking is lighter and less invasive than mudjacking, and it reacts within seconds. Liquimix manufactures slab lifting foam in Australia and supplies it to professional applicators. Sunken concrete

Key Takeaways To stop water leaking through cracks in a basement car park, inject the cracks with a hydrophilic polyurethane resin. The CrackShot 150, for example, reacts with water to create the perfect seal, even while it’s still leaking. Use epoxy injection for dry, structural cracks instead. The right choice

Key Takeaways The best waterproof coating for a flat concrete roof is a UV-stable, liquid-applied membrane, typically polyurethane or a polyurea hybrid. It forms a seamless layer with no joints, preventing leaks. Trafficable systems (pedestrian-friendly surfaces for walking) suit rooftop terraces, and lifespan depends on UV exposure, membrane thickness, ponding