Recoatability of Opalon-S30 and Opalon-W45 over Hybron-H90

Technical Report

RECOATABILITY OF OPALON-S30 AND OPALON-W45 OVER HYBRON-H90

 

Date: 1 November 2023

 

INTRODUCTION

The recoatability of Opalon-S30 and Opalon-W45 over Hybron-H90. 

TESTING

Testing was completed @25 Deg C in laboratory conditions. Adhesion for Opalon-S30 and Opalon-W45 to Hybron-H90 after 8 Days, still has good adhesion.

Recoat Times Product
S30 W45
After cooled - 10 mInutes Good Good
30 minutes Good Good
1 hr Good Good
3 hr Good Good
17 Hr Good Good
20 Hr Good Good
22.5 Hr Good Good
28 Hr Good Good
2 Days Good Good
8 Days Good Good
Recoat window will be reduced by UV**

 

New Recoatability Table

 

Recoating Opalon-S30 and Opalon-W45 over Hybron-H90
Substrate Temperature Minimum Recoat Time Maximum Recoat Time
5°C 15 minutes 8 Days
10°C 15 minutes 8 Days
15°C 15 minutes 8 Days
25°C 15 minutes 8 Days
40°C 15 minutes 4 Days

 

TECHNICAL DOWNLOADS

Recoatability Report

CONCLUSION

Hybron-H90 provides the best recoat windows for Opalon-S30 and Opalon-W45.