Spitting Spray Pattern? Troubleshooting Your Fusion Gun and Reactor When Spraying Tufflon or Elaston

A spitting spray pattern stops a job fast. The fan breaks into streaks, droplets and thick globs land on the substrate, and the coating loses its seamless finish. Every Australian applicator spraying Tufflon or Elaston through a Graco Fusion gun and Reactor proportioner meets this problem at some point, and every cause has a fix.

This guide walks through the diagnosis in the order that finds the fault fastest: pressure, temperature, material condition, the Fusion gun, then the Reactor. Work through each step before moving to the next.

What a Spitting Spray Pattern Tells You

Spitting means the two components, ISO (A side) and resin (B side), are not reaching the mix chamber at the right pressure, temperature or ratio. The coating cures unevenly when that happens, and the surface shows it.

Symptom Most Common Cause
Spitting at trigger pull, then clears Pressure imbalance or air in the lines
Constant spitting through the whole pass Cold material or a blocked mix chamber
Spitting plus soft, tacky or foamy coating Off-ratio spray or moisture contamination
Streaks with one hard edge on the fan Partial blockage in a gun port or check valve
Spitting that worsens as the day warms up Heater setpoints too high or a failing pump seal

Step 1: Check Your Pressure Balance First

Pressure imbalance causes more spitting complaints than any other fault. Read the A and B gauges on the Reactor while the gun is triggered, and compare them with the dynamic pressure readings on the display.

  • Balanced pressure means the A and B gauges sit within a few percent of each other during spraying. Tufflon and Elaston both need balanced pressure to hold ratio.
  • Imbalanced pressure means one gauge reads lower. The ISO side drops when a filter, hose or port restricts flow. The resin side drops when the material is cold and thick.

Stall the pumps and check the pressure holds on both sides. A side that bleeds down has a leaking check valve or worn packing, and the proportioner is delivering off-ratio material until you repair it. Repair the pump before spraying another litre.

Step 2: Confirm Heater and Hose Temperatures

Temperature controls viscosity, and viscosity controls atomisation. Tufflon and Elaston each publish primary heater and hose temperature setpoints in their technical data sheets. Set the Reactor to those figures, not to a number remembered from a different product.

  1. Set the primary heaters to the data sheet temperature.
  2. Set the heated hose to match, and keep the hose bundle uncoiled and off hot or cold surfaces.
  3. Check the hose temperature sensor (FTS) is attached to the hose and reading correctly.
  4. Allow full heat-up before spraying. Spraying at partial temperature produces spitting every time.

A hose that is too cool leaves material thick at the gun. A hose that is too hot over-thins the resin and accelerates reactivity in the mix chamber. Both produce a broken fan.

Step 3: Condition Your Material and Control Moisture

Material conditioning matters as much as machine settings. Drums stored in a cold shed or a hot container on an Australian site arrive at the pump at the wrong temperature, and the Reactor spends the first part of the day fighting that.

  • Store Tufflon and Elaston drums at the temperature the data sheet specifies, and condition them before the job.
  • Stir or recirculate the resin side as the product instructions direct, so settled pigments and fillers return to suspension.
  • Keep ISO sealed. ISO reacts with humidity, forms crystals and clogs filters, check valves and gun ports.
  • Fit a desiccant dryer on the ISO supply drum.
  • Never leave drums open between shifts.

Moisture in the resin side produces foam and bubbles. Those bubbles arrive at the gun as spitting and leave pinholes in the cured film. Replace a contaminated drum rather than spraying it.

Step 4: Troubleshoot the Fusion Gun

The Fusion gun (PC, AP, CS or MP) is the most frequent source of a localised spitting spray pattern after pressure and temperature are confirmed.

Mix chamber size. Match the chamber to the material and your output. A chamber too large for the flow rate starves the pattern, and a chamber too small over-pressurises it. Check the Tufflon or Elaston guidance for your gun model and fit the correct chamber.

Mix chamber and port condition. Remove the mix chamber and inspect it.

  • Clean the A and B ports in the mix module with the correct cleaning tools, not wire or drill bits.
  • Replace any chamber with scored, chipped or rounded edges.
  • Confirm the chamber seats square and the module screws are tight.

Check valves and screens. Strip the inlet manifold. Clean or replace the A and B check valves and the gun inlet screens. Crystallised ISO shows as hard white or yellow deposits, and one blocked screen starves one side of the gun instantly.

O-rings and seals. Replace worn o-rings on the mix module, the manifold and the fluid inlet fittings. A leaking o-ring draws air into the stream, which produces spitting at every trigger pull.

Step 5: Troubleshoot the Reactor Proportioner

When the gun checks out, inspect the Reactor.

Pump condition. Watch pump behaviour during spraying. A pump that runs fast and drops pressure on the upstroke or downstroke has a worn check valve, a damaged piston seal or worn packing. Rebuild the pump with genuine seals and throat packing.

Inlet strainers. Clean the A and B inlet strainer screens every shift. Resin carries fillers that load the screen, and a loaded screen cavitates the pump.

Fluid filters and manifold. Check the in-line filters and replace any restricted element.

Transfer pumps and supply lines. Confirm the transfer pumps deliver a full, air-free supply. Air in the line produces spitting that clears briefly, then returns. Bleed the lines and tighten every fitting on the supply side.

Power supply. Reactors need stable voltage. Generators on Australian sites that sag under load cause heater faults and erratic pressure. Use a correctly rated generator with a clean output, and check that extension leads match the Reactor’s current draw.

Step 6: Allow for Australian Site Conditions

Australian job sites change the process.

  • Hot, humid conditions in Queensland and the Northern Territory raise moisture risk. Protect ISO, spray early and watch substrate and dew point.
  • Cold mornings in Victoria, Tasmania and the Alpine regions slow material heat-up. Condition drums and allow longer hose warm-up.
  • Wind and dust push contamination into open drums and onto the gun. Shelter the rig and keep lids on.
  • Remote sites place spare seals, o-rings and mix chambers.

Frequently Asked Questions

Why does my Fusion gun spit only when I first pull the trigger?
Air or off-ratio material sits in the gun after a pause. Purge briefly into a waste container, confirm pressure balance, then spray.

Does a spitting spray pattern affect the cured Tufflon or Elaston film?
Yes. Spitting delivers off-ratio material, which cures soft, tacky or brittle and lowers adhesion and waterproofing performance. Remove and re-coat any affected area.

How often must I replace the mix chamber?
Replace it on a schedule set by your spray volume and the manufacturer’s guidance, and immediately when the fan narrows or the edges wear.

Is spitting a gun problem or a Reactor problem?
Check the Reactor pressures and temperatures first, then the gun. Pressure and temperature faults account for most cases, and gun faults follow.

Need Your Graco Fusion Gun or Reactor Serviced? Liquimix Delivers.

Spitting spray patterns cost you time, material and finished results. When the troubleshooting steps above do not clear the fault, hand the equipment to the team that knows Tufflon and Elaston application.

Liquimix offers a Graco equipment service for Australian applicators. Our technicians service Fusion guns and Reactor proportioners, restore pressure balance and heater performance, and return your rig ready to spray.

Book your Graco equipment service with Liquimix. Contact us today.

unnamed (21)

Liquimix Product & Equipment Search

"At LiquiMix my staff and I are fully committed to ensuring your success. With our team of industrial chemists, qualified tradesmen and experienced coatings professionals we are able to draw upon a vast resource of experience in order to give you the best chance of success in each of your projects. We consider it a privilege to work alongside you."
Neill Barrell
Managing Director

get in touch