Warm Roof Systems: How PURL-SP32 Closed-Cell Insulation Foam and Elaston-W80 Pure Polyurea Work Together

How Liquimix’s Warm Roof System Supports Australian Building Performance

Roof insulation plays an important role in the energy efficiency, comfort, and long-term performance of Australian buildings. From homes exposed to summer heat to commercial warehouses and industrial facilities, a roof must provide shelter while managing heat transfer and protecting the building from weather.

One approach to improving roof performance is Liquimix’s warm roof system, which combines Purl – SP32 insulation with a Class III water proofing membrane, Hybron H90 and Elaston UVX to help maintain a more consistent temperature within the building envelope. When designed correctly, a warm roof helps reduce heat transfer, improve indoor comfort, and significantly minimise the risk of condensation within the roof assembly.

Two products that serve different functions in roof and building protection are PURL-SP32 closed-cell spray polyurethane foam and Elaston pure polyurea waterproofing membrane from Liquimix.

In this guide, we explore how Liquimix’s proven warm roof system works, the functions of Purl – SP32 and Elaston, and the key considerations for Australian roofing contractors and building professionals.

Understanding PURL-SP32 Closed-Cell Spray Foam Insulation

PURL closed-cell spray foam applied to a roof surface during a professional spray foam application
PURL closed-cell spray foam applied to a roof surface as part of a thermal insulation application.

What Is PURL-SP32?

PURL-SP32 is a two-component spray polyurethane foam designed to form a rigid, closed-cell insulation material after application. It is a foam suitable for insulating homes, roofs, factories, and other structures. It is processed using specialised plural-component spray equipment because of its rapid reaction time.

Specification of PURL-SP32

MIX RATIO 1:1
PROCESSING TEMPERATURE (°C) 45°C
PROCESSING PRESSURE (PSI) 1,500
CREAM TIME (SEC) @ 21°C 5-7 seconds
RISE TIME (SEC) @ 21°C 10-15 seconds
FREE RISE DENSITY (KG/M ) @ 21°C 30 – 35 kg/m³
FIRE TEST – SELF EXTINGUISHING (SEC) (KG/M ) @ 21°C 0-3
THERMAL CONDUCTIVITY (K-FACTOR) @ 22.5°C 0.022 W/mK
R-VALUE (@ 50MM) 2.05
CLOSED CELL CONTENT >95%
VOC EMMISIONS 0.01 over 24 hrs

How Does Purl SP32 Foam Help Insulate a Roof?

Liquimix PURL-SP32 is a closed-cell spray polyurethane foam designed to provide thermal insulation. Its enclosed cellular structure and low thermal conductivity help reduce heat transfer through the roof assembly.

When applied at the specified thickness and in the appropriate location, PURL-SP32 supports the thermal performance of suitable roof systems.

Advantages include:

1. Thermal insulation

PURL-SP32 has a thermal conductivity of 0.022 W/m·K. This low value helps resist heat transfer, making the foam relevant to metal-roofed buildings exposed to significant solar heat gain. The insulation performance is determined by the installed foam thickness and the overall roof design.

2. Application to roof profiles

As a spray-applied foam, PURL-SP32 expands to conform to suitable roof surfaces and profiles. Correct application helps achieve consistent coverage and the specified insulation thickness, including around appropriately detailed roof features.

3. Support for air-leakage control

A continuous, properly installed PURL-SP32 layer helps limit uncontrolled air movement through gaps in the insulated surface.

4. Insulation for different building types

PURL-SP32 is marketed for roof insulation applications in homes, factories, and other structures. Its installation must comply with the roof assembly design, substrate requirements, fire safety regulations, moisture control measures, and applicable building standards.

Is PURL-SP32 Suitable for Metal Roof Insulation?

PURL-SP32 provides thermal insulation for metal roof applications. It functions as the insulation layer within the roof assembly and helps reduce heat transfer through the roof structure.

Before installation, the metal substrate must be assessed, and the roof design must address condensation control, drainage, and vapour control requirements.

PURL-SP32 provides thermal insulation and does not replace the waterproofing or moisture-management components required for a complete roof system.

Understanding Elaston-W80 Pure Polyurea Waterproofing Membrane

Digester roof protected with Liquimix Elaston-W80 pure polyurea waterproofing membrane during an industrial construction project.
Elaston-W80 pure polyurea applied as a protective waterproofing solution for a digester roof, helping provide a seamless membrane for demanding industrial environments.

What Is Elaston-W80?

Elaston-W80 is waterproofing-grade pure polyurea membrane. It is a spray-applied material that cures rapidly to form a continuous, flexible lining.

Elaston-W80 is used for waterproofing applications including rooftops, balconies, retaining walls, and wet areas.

Specification of Elaston-W80

Elaston-W80 has several published properties relevant to waterproofing and protective coating applications.

Volume Solids 100%
Theoretical Coverage 1.5L / Square meter @ 1500 Microns (1.5mm) DFT
Finish Pigmented
Colour Various
Gloss Semi-Gloss
Mixing Ratio 1:1 by volume
Gel Time 6 seconds
Typical Thickness 1500 Microns Dry Film Thickness
Cleaner Reactor Flush and Swell
Flash Point >149°C

How Does Elaston-W80 Help Protect a Roof?

1. Seamless waterproofing

When applied continuously over a suitable prepared substrate, Elaston-W80 forms a seamless membrane that helps prevent water from passing through the protected surface.

2. Flexibility and movement accommodation

Elaston-W80’s published elongation of more than 400% indicates its ability to stretch under test conditions. Its high elongation allows the cured membrane to accommodate substrate movement

3. Rapid setting

Elaston-W80 cures rapidly after spray application, supporting efficient application and helping reduce the time required for the membrane to set.

4. Protective surface

Elaston-W80 forms a continuous polyurea membrane that provides a waterproofing barrier over a suitable, properly prepared substrate when applied.

Is Elaston-W80 Suitable for Roof Waterproofing?

Elaston-W80 is used for roof waterproofing applications to protect roof surfaces against water penetration.

Before application, the substrate must be properly assessed and prepared in accordance with the product’s technical specifications. The roof system must also provide adequate drainage and meet the requirements for environmental exposure, UV protection, and applicable waterproofing standards.

How PURL-SP32 and Elaston-W80 Work Together in a Warm Roof System

A warm roof system combines thermal insulation and waterproofing to reduce heat transfer and protect the roof from water penetration.

When specified as part of a properly designed roof assembly, these products serve complementary functions:

Thermal performance :

PURL-SP32 is a closed-cell spray polyurethane foam that provides thermal insulation by reducing heat transfer through the roof structure.

Waterproofing :

Elaston-W80 forms a continuous waterproofing membrane that protects the roof surface against water penetration.

Roof protection :

The roof assembly combines PURL-SP32 insulation and Elaston-W80 waterproofing to address thermal insulation and water protection requirements.

Coordinated design :

Proper product selection, substrate preparation, installation sequence, and roof detailing are essential to achieving the specified performance of the complete roof assembly. Both products must be installed in accordance with their technical data sheets and the roof design requirements.

Key Considerations for Australian Roofing Applicators

A successful warm roof installation requires appropriate substrate preparation, insulation design, moisture control, waterproofing, and compliance with Australian building requirements.

1. Roof Substrate and Surface Preparation

Inspect the roof for corrosion, damage, contaminants, existing coatings, and drainage issues. Prepare the substrate according to the technical requirements of PURL-SP32 and Elaston-W80 to support proper adhesion and application.

2. Insulation Thickness and Thermal Performance

Determine the required insulation thickness based on the building’s climate zone, roof construction, and target thermal performance.

PURL-SP32 has a published R-value of 2.05 at 50 mm thickness. The total roof R-value depends on the complete assembly and calculation method.

3. Condensation and Vapour Control

Assess internal humidity, air leakage, vapour control, and the roof assembly’s ability to manage moisture. The placement of insulation and vapour control layers must follow the roof design to reduce condensation risks.

4. Waterproofing Details and Drainage

Ensure the roof has appropriate falls, functioning drainage outlets, and correctly detailed flashings, joints, penetrations, and membrane terminations. Proper detailing helps maintain the continuity of the waterproofing layer.

5. Fire Safety and Building Compliance

Assess the complete roof assembly against the applicable National Construction Code (NCC), relevant Australian Standards, fire-safety requirements, and project specifications. Individual product test results do not establish compliance of the entire assembly.

6. Applicator Training and Spray Equipment

PURL-SP32 and Elaston-W80 require appropriate spray equipment and application procedures. Follow each product’s technical data sheet for component handling, mixing ratio, material temperature, application thickness, safety equipment, and quality checks.

Applications for Liquimix Warm Roof Insulation and Waterproofing

A properly designed roof assembly using spray foam insulation and a waterproofing membrane considered for different types of Australian buildings.

1. Commercial and Industrial Buildings

Warehouses, workshops, and industrial facilities benefit from roof insulation that helps reduce heat transfer through large roof areas.

2. Residential Buildings

PURL-SP32 provides thermal insulation for residential roof applications, helping reduce heat transfer through the roof. Elaston-W80 provides a flexible, seamless waterproofing membrane for suitable residential roof surfaces.

3. Flat and Low-Slope Roofs

Flat and low-slope roofs require effective waterproofing, drainage, and moisture management. Elaston-W80 forms a continuous waterproofing membrane over a suitably prepared substrate, while PURL-SP32 provides thermal insulation as part of the roof assembly.

4. Agricultural and Storage Facilities

Agricultural sheds and storage buildings benefit from roof insulation that helps limit heat transfer. PURL-SP32 provides thermal insulation for these building applications, while Elaston-W80 provides waterproofing for suitable roof surfaces.

Planning a Warm Roof Project? Explore Liquimix Solutions

Whether you’re working on a commercial building, industrial facility, or roof renovation, Liquimix offers products designed for insulation and waterproofing applications.

Explore PURL-SP32 and Elaston-W80 to find out how these products may fit your next roofing project. Consult the technical data sheets and confirm system compatibility before specifying them as a combined warm roof solution.

Contact Form

"*" indicates required fields

Name*

Liquimix Product & Equipment Search

"At LiquiMix my staff and I are fully committed to ensuring your success. With our team of industrial chemists, qualified tradesmen and experienced coatings professionals we are able to draw upon a vast resource of experience in order to give you the best chance of success in each of your projects. We consider it a privilege to work alongside you."
Neill Barrell
Managing Director

get in touch